Products

Search this category

Refine your search

Contact Us

Join our Mailing List

Data Loggers

Single, dual, four and 8 channel Data Loggers, including comprehensive software for data storage and report generation.

Data Loggers

Single, dual, four, and eight channel data loggers are available to measure a wide variety of AC, DC, pulse, and environmental parameters such as temperature, pressure, and flow. Comprehensive software is included for instrument configuration, data download, and report generation. Wired and wireless communication options allow access to the data locally or anywhere in the world. There are many compatible current probes available as accessories for select models.

  • Simple Logger® II Model CL601

    Cat. #2126.01
    1-Channel, TRMS, Clamp-on, 0 to 600AAC, DataView® Software

    One channel recording device that performs line tracking by taking 64 samples over one line cycle. Performs frequency tracking over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Records TRMS at a rate of up to eight times per second. Performs a variety of recording tasks with easy and intuitive setup from a computer using the free DataView® software (included).

  • Simple Logger® II Model L101

    Cat. #2126.02
    1-Channel, TRMS, 0 to 1VAC, DataView® Software

    One channel recording device that performs line tracking by taking 64 samples over one line cycle. Harmonic measurements are calculated from these 64 samples. Records TRMS at a rate of up to eight times per second. TRMS calculations are performed on a single line cycle.

  • Simple Logger® II Model L102

    Cat. #2126.03
    2-Channel, TRMS, 0 to 1VAC, DataView® Software

    Two channel recording device that performs line tracking by taking 64 samples over one line cycle. Harmonic measurements are calculated from these 64 samples. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Records TRMS at a rate of up to eight times per second. TRMS calculations are performed on a single line cycle. Features easy and intuitive setup from a computer using DataView® software.

  • Simple Logger® II Model L111

    Cat. #2126.04

    1-Channel, TRMS, 0 to 1AAC, DataView Software (Discontinued)

  • Simple Logger® II Model L261

    Cat. #2126.05
    1-Channel, TRMS, 600VAC/DC, DataView® Software
    One channel recording device that performs line tracking by taking 64 samples over one line cycle. Harmonic measurements are calculated from these 64 samples. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Records TRMS at a rate of up to eight times per second. TRMS calculations are performed on a single line cycle. Features easy and intuitive setup from a computer using DataView software.

  • Simple Logger® II Model L322

    Cat. #2126.06

    2-Channel, 4 to 20mADC, Current, DataView® Software
    (Discontinued, replaced by Model L452)

  • Simple Logger® II Model L432

    Cat. #2126.07

    2-Channel, DC ±100mV/1V/10VDC, DataView® Software
    (Discontinued, replaced by Model L452)

  • Simple Logger® II Model L642

    Cat. #2126.08
    2-Channel, Temperature Thermocouple, DataView Software

    Two channel thermocouple data logger. With J, K, T, N, E, R or S thermocouples, it measures from -346° to + 1767°F (-210° to 964°C) with resolution to 0.1° (range dependent). Features include Extended Recording Mode (XRM) and delayed start time. Includes easy and intuitive setup from a computer using DataView software.

  • Simple Logger® II Model AL834

    Cat. #2126.14
    4-Channel, TRMS, Bluetooth, AmpFlex® 300/3000AAC, DataView® Software

    Four channel AC current data logger with four integral flexible 24” current sensors. Two measurement ranges of up to 300A and 3000A. Data logger housing and current sensors are rated IP 65 for water resistance. Up to 1,000,000 measurements can be stored in internal nonvolatile memory. Includes easy and intuitive setup from a computer using DataView software.

  • Data Logger Model L452

    Cat. #2153.51
    Data Logger Model L452 (2-Channel, w/LCD, 100mV/1V/10VDC, 4 to 20mADC, Event & Pulse, DataView® Software
    Two channel data logger for recording DC voltage, DC current, pulses and events. Connect to various sensors to measure pressure, temperature, flow, humidity and many other types of values. Also records events such as machine run time. Communicates via USB or Bluetooth for configuration and data transfer. Setup from a computer via free DataView software, or via the front-panel interface.

  • Simple Logger® II Model L481

    Cat. #2126.25
    1-Channel, DC, ±850V, DataView® Software
    Single channel bipolar DC logger for measuring voltage –850 to +850VDC. Features include Extended Recording Mode (XRM®) and delayed start time. Up to 240,000 measurements can be stored in internal memory. User programmable scale and engineering units are available. Includes easy and intuitive setup from a computer using DataView software.

  • Simple Logger® II Model L562

    Cat. #2126.35
    2-Channel, TRMS, Voltage & Current, DataView® Software
    Two channel voltage/current data logger. Features include Extended Recording Mode (XRM®) and delayed start time. Records TRMS at a rate of up to eight times per second. TRMS calculations are performed on a single line cycle. Includes easy and intuitive setup from a computer using DataView® software.

  • Simple Logger® II Model ML912

    Cat. #2126.37
    2-Channel, TRMS, MiniFlex®, 100/1000AAC, DataView® Software
    Two channel AC current data logger with two user selectable measurement ranges of 0 to 100A and 0 to 1000A. Frequency tracking performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Line tracking is performed with 64 samples over one line cycle; harmonic measurements are calculated from these 64 samples. Includes easy and intuitive setup from a computer using DataView® software.

  • Simple Logger® II Model ML914

    Cat. #2126.40
    4-Channel, TRMS, Bluetooth, MiniFlex®, 100/1000AAC, DataView® Software
    Four channel AC current logger that measures in two user selectable ranges (100A and 1000A). Line tracking takes 64 samples over one line cycle; harmonic measurements are calculated from these 64 samples. Frequency tracking is performed around the nominal line frequency 50 or 60Hz. Stores TRMS at user programmable rates of up to eight times per second. TRMS calculations are performed on a single line cycle. Includes four integral 6" MiniFlex® flexible current probes. Includes easy and intuitive setup from a computer using DataView® software.

  • Data Logger Model DL-1080

    Cat. #2134.61
    8 Analog & 8 Digital Channel, No Display
    Eight channel data logger for measuring analog, digital and other types of data with high resolution and speed. Up to 128 math channels can be used to perform operations on the measured values. Up to 32 alarm events can be detected, allowing output activations, e-mails, and SNMP trap sending.

  • Data Logger Model DL-1081

    Cat. #2134.62
    8 Analog & 8 Digital Channel, Display
    Eight channel data logger for measuring analog, digital and other types of data with high resolution and speed. Up to 128 math channels can be used to perform operations on the measured values. Up to 32 alarm events can be detected, allowing output activations, e-mails, and SNMP trap sending. RS485 interface can operate as a Modbus RTU master or slave. A 10/100Mbps Ethernet interface allows access through a browser HTTP, FTP client and server, e-mails sending SMTP, SNMP, and Modbus TCP.

  • Simple Logger® II Model L564

    Cat. #2126.36

    4-Channel, TRMS, Bluetooth, Voltage & Current, DataView® Software
    (Discontinued)

  • Simple Logger® II Model L104

    Cat. #2126.10

    4-Channel, TRMS, Bluetooth, 0 to 1VAC, DataView® Software
    (Discontinued)

Show Discontinued Products

DISCOVER THE CHAUVIN ARNOUX GROUP

©2018 Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.
Contact 
AEMC Data Loggers
Single-channel datalogger, to channel datalogger, multichannel datalogger, AC voltage data logger, DC voltage datalogger, AC current datalogger, DC current datalogger, pulse, datalogger, event datalogger
Monitor your facility’s data. AEMC data loggers record a broad spectrum of electrical and environmental measurements. Most models include DataView report generation software for data display and analysis.