Model | Cat. # | Description | List Price | Quantity/Status | Distributor Stock Check |
---|---|---|---|---|---|
6550 | 2130.31 | Megohmmeter Model 6550 | $5,295.00 | In stock at factory. Find a Distributor |
|
|
AC/DC Voltage Measurement | |
Range | 1 to 4000V |
Accuracy | 1 to 99.9V: ±(1% R + 5ct) 100 to 4000V: ±(1% R + 1ct) |
Resolution | 1 to 99.9V: 0.1V 100 to 999V: 1V 1000 to 4000V: 2V |
Frequency Range | 1 to 2500V: DC or 15 to 500Hz 2501 to 4000V: DC |
Input Impedance | 3MΩ |
Insulation Measurement | |
Test Voltage / Resistance Range | 500V: 10kΩ to 2TΩ 1000V: 10kΩ to 4TΩ 2500V: 10kΩ to 10TΩ 5000V: 10kΩ to 15TΩ 10,000V: 10kΩ to 25TΩ |
Measurement Accuracy | 10kΩ to 39.99GΩ: ±(5% R + 3ct) 40.0GΩ to 10.00TΩ: ±(15% R + 10ct) 400GΩ to 3.999TΩ: ±(15% R + 10ct) @ 500 and 1000V only 4.00 to 10.00TΩ: ±(20% R + 10ct) @ 2500V 4.00 to 15.00TΩ: ±(20% R + 10ct) @ 5000V 4.00 to 25.00TΩ: ±(20% R + 10ct) @ 10000V |
Variable Voltage | 40 to 10,000V |
Auto Discharge | Discharge time < 27s/µF from Vtest to 25V @ 10,000V |
Live Circuit Indicator | Inhibit test if terminal voltage > 25V prior to initialization of test |
General Features | |
Programmable Alarm | Yes |
DAR – PI – DD – R(t) | Yes |
Ramp Mode | Programmable start and end voltage, duration |
Step Mode | Up to 10 steps (voltage and duration configurable for each step) |
Capacitance Measurement | 0.005 to 19.99µf |
Leakage Current Measurement | 0 to 8 mA |
Short Circuit Current | ≤5mA DC (adjustable in setup mode) |
Calculation of R at Reference T° | Yes |
Display | Graphic |
Memory | 256 registers (80,000 points) |
Communication | USB optically-isolated port |
Software | DataView Software (included) |
Power Supply | 2 x rechargeable 9.6V NiMH battery pack; external 90-260V, 50/60Hz |
Battery Life | ≥ 2 h at 10,000V (insulation test) |
Charging Time | 6 hours approximately (charging allowed during tests) |
Dimensions | 13.4 x 11.8 x 7.9” (340 x 300 x 200mm) |
Weight | 13.7 lbs (6.2kg) |
Altitude Operating | 6562' (2000m) |
Operating Temperature | 32° to +95°F (0° to +35°C) ≤75% RH |
Storage Temperature | -40° to +158°F (-40° to +70°C) ≤90% RH |
IP Rating | IP 65 |
Safety Compliance | IEC 61010-1, IEC 61557, 1000V CAT IV, Pollution Degree 2![]() |
User Manuals
Models 6550 and 6555
Models 6550 and 6555 - Spanish
Models 6550 and 6555 - French
Models 6550 and 6555 Red Leads
Megohmmeter Calibration Checker
Quick Start Guide
Datasheets
Brochure
Comparison Charts
Software/Firmware
DataView Software
Ver. 3.61.0008 Open Release Notes for the latest updates | Models Supported by DataView
Release Date: November 12, 2019
DataView Complete (Report generation and control panels)
Executable: Version 3.61.0008 - .exe
Zipped File: 471MB Version 3.61.0008 - .zip
IMPORTANT:
- Back-up all template files before installation to ensure that they do not get overwritten.
- Uninstall previous versions of DataView before installing a new version.
- PQL Loggers and Sentinel Series are no longer supported by DataView. See bottom of the page for a compatible version
Supported Operating Systems:
Windows 7 (32 & 64 Bit)
Windows 8/8.1 (32 & 64 Bit)
Windows 10 (32 & 64 Bit)
Click here for the Minimum System Requirements
Below are the individual DataView component installers
This is the DataView core report generation software without any control panels
Release Date: 07/15/19
77MB Download v3.61.0008 .zip format
This control panel supports models: L452, 1510, 1821, 1822, 1823, 1110, 1246, 1227, 10101, and 10141
Release Date: 02/25/19
75MB Download v2.02.0085 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports model 8510
Release Date: 02/25/19
40MB Download v1.02.0006 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports model 6417
Release Date: 02/25/19
57MB Download v1.02.0004 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports models: 6470-B, 6471, and 6472
Release Date: 02/25/19
44MB Download v1.05.0003 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports models: 6116, 6116N, and 6117
Release Date: 02/25/19
65MB Download v1.07.0022 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports models: 1060, 5060, 5070, 6550, 6555, 6526, 6532, and 6534
Release Date: 02/25/19
57MB Download v4.02.0071 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports models: 6240, 6250, 6255, and 6292
Release Date: 02/25/19
47MB Download v1.07.0005 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports models: 8220, 8230, 3945-B, 407, 607, and 8335 (if using firmware ≤2.8)
Release Date: 09/17/19
70MB Download v3.08.0019 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports models: 8333, 8335 (if using firmware >2.8), 8336, 8435, 8436
Release Date: 11/12/19
67MB Download v1.07.13010 .zip format
This control panel requires DataView version 3.61.0008 or higher
This control panel supports models: PEL102, PEL103, and PEL105
39MB Download v2.5.12642 .zip format
Release Date: 06/03/19
This control panel requires DataView version 3.61.0008 or higher
This control panel supports models: L261, L264, CL601, L702, L101, L102, L104, L642, L111, L432, AL834, ML912, ML914, L322, L562, L564, L404, and L481
Release Date: 10/17/19
63MB Download v1.05.0009 .zip format
NOTE: PQL Loggers and Sentinel Series are no longer supported by DataView.
To obtain an older version of DataView that is compatible for these instruments, click the link below:
Download v3.09.0008 - .zip format
Supported Operating Systems:
Windows XP
Windows 7 (32 & 64 Bit)
Windows 8/8.1 (32 & 64 Bit)
Windows 10 (32 & 64 Bit)
LabView Drivers
Megohmmeters | |||
Ver. 1.0 | Model 1060 | Overview PDF | |
Ver. 1.1 | Models 5060 & 5070 | Overview PDF | |
Ver. 1.0 | Models 6550 & 6555 | Overview PDF | |
Power Quality & Energy | |||
Ver. 1.0 | Models 8333, 8435, 8335, & 8336 | Overview PDF | |
Ver. 1.0 | Models PEL 102 & 103 | Overview PDF | |
Simple Logger II Series | |||
Ver. 1.0 |
Overview PDF |
Megohmeter Model 655x Series - Firmware
Important: To ensure that there is no loss of data, download all data from the instrument before installing any software and firmware updates. | |||||
Version 3.1 / 2.1 | Release Date: | ||||
11MB |
Firmware Version 3.1 / 2.1 | Dec. 12, 2017 | |||
|
|||||
Application Notes
Battery Recharge Time / Rechargeable NiMH Notice
Tiempo de recarga de las baterías / Aviso de NiMH recargable
Test Lead Compensation - Models 6550, 6555
An Introduction to Insulation Resistance Testing
True RMS, True InRush, and True Megohmmeter
Megohmmeter Calibration Checker and Ground Resistance Checker
Megohmmeter Insulation Testing After Flood Damage
Forms
Technical Bulletins
Video
Understanding Insulation Resistance Testing
Model 6555/6550 Lead Compensation Feature Explained
What's New in DataView 3.50
Model | Cat. # | Description | List Price | Quantity/Status | Distributor Stock Check |
---|---|---|---|---|---|
![]() |
2119.56 | Fuse, Set of 3, 0.1A, 660V, 20kA, 6x32mm for Models 1050/1060/6550/6555 | $35.50 |
|
|
![]() |
2119.82 | Multi-purpose Large Canvas Bag Dimensions: 22 x 10.5 x 12" |
$130.00 |
|
|
![]() |
2133.72 | Compact tool bag for field use. 12 Exterior and 14 Interior pockets Dimensions: 13.0 x 9.8 x 9.5" |
$33.50 |
|
|
![]() |
2135.41 | Optical USB Cable – Replacement for Models 6240, 6470/6470-B, 6471, 6472, 6550 ,6555, 8220, 8230 & MTX 328x Series | $57.00 |
|
|
![]() |
2135.43 | Inverter - 12VDC to 120VAC 200 Watt for Vehicle Use (use with Ground Testers, Megohmmeters & Micro-ohmmeters) | $80.00 |
|
|
![]() |
2151.14 | Lead - Replacement, Set of 3, Color-coded 9 ft (15kV) Integral Leads & Clips for Models 6550 & 6555 | $555.00 | Consult Factory for Availability |
|
![]() |
2151.15 | Lead - Replacement 1 ft Jumper Lead (15kV) for use with Megohmmeter Models 6550 and 6555 | $136.50 |
|
|
![]() |
2151.17 | Lead – Set of 3, 9 ft Color-coded (Red/Blue/Black) Shielded Safety Leads w/Hippo Clips (15kV) for Models 6550 & 6555 | $675.00 |
|
|
![]() |
2151.18 | Lead - One Shielded Safety Lead (black) 25 ft w/Hippo Clips (15kV) for use with Megohmmeter Models 6550 and 6555 | $380.00 | Consult Factory for Availability |
|
![]() |
2151.19 | Lead - One Shielded Safety Lead (blue) 25 ft w/Hippo Clips (15kV) for use with Megohmmeter Models 6550 & 6555 | $313.00 |
|
|
![]() |
2151.20 | Lead - One Shielded Safety Lead (red) 25 ft w/Hippo Clips (15kV) for use with Megohmmeter Models 6550 & 6555 | $313.00 |
|
|
![]() |
2151.21 | Lead - One Shielded Safety Lead (black) 45 ft w/Hippo Clips (15kV) for use with Megohmmeter Models 6550 & 6555 | $509.00 | Consult Factory for Availability |
|
![]() |
2151.22 | Lead - One Shielded Safety Lead (blue) 45 ft w/Hippo Clips (15kV) for use with Megohmmeter Models 6550 & 6555 | $438.00 |
|
|
![]() |
2151.23 | Lead - One Shielded Safety Lead (red) 45 ft w/Hippo Clips (15kV) for use with Megohmmeter Models 6550 & 6555 | $438.00 | Consult Factory for Availability |
|
![]() |
5000.14 | Power cord 115V for Micro-ohmmeters, Megohmmeters, Power Instruments, Oscilloscopes & Ground Testers | $8.50 |
|
|
![]() |
5000.30 | Probe - black test probe {Rated 1000V CAT IV, 15A, UL} replacement for Megohmmeter lead sets | $6.00 |
|
|
![]() |
5000.31 | Probe - red test probe (1000V CAT IV, 15A, UL) | $6.00 |
|
|
![]() |
5000.66 | Megohmmeter calibration checker - provides two test resistances of 150kO and 100MO.
NOTE: The 150kO terminal accepts test voltages up to 1000V. The 100MO terminal accepts voltages up to 2500V. |
$104.00 | Consult Factory for Availability | |
![]() |
5100.02 | Latches - Replacement set of 2 for use with AEMC Yellow cases | $8.50 |
|
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|
||||||||||
|